HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide April 2004 (First Edition) Part Number 359539-001

Strona 2 - Audience Assumptions

10 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Rear Panel Components Item Description 1 PCI-X expansion slot 1, 6

Strona 3 - Contents

100 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide OS Boot Problems Flowchart Symptoms: • Server does not boot a

Strona 4

Troubleshooting 101

Strona 5

102 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 7 "HP Insight Diagnostics (on page 80)" Server Fault

Strona 6

Troubleshooting 103 Item Refer to 8 • "Hardware Problems (on page 105)" • Server maintenance and service guide, located on the Document

Strona 7 - Front Panel Components

104 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide

Strona 8 - Front Panel LEDs and Buttons

Troubleshooting 105 not faulty. Procedures for All ProLiant Servers The procedures in this section are comprehensive and include steps about o

Strona 9

106 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 5. Have a qualified electrician check the line voltage to be sure it

Strona 10 - Rear Panel Components

Troubleshooting 107 6. Be sure each circuit breaker is in the On position, or replace the fuse if needed. If this occurs repeatedly, contact

Strona 11 - Rear Panel LEDs and Buttons

108 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Loose Connections Action: • Be sure all power cords are securely con

Strona 12 - System Board Components

Troubleshooting 109 − Installation of a SCSI device without termination or without proper ID settings − Setting of an IDE device to Master/Slave w

Strona 13 - System Maintenance Switch

Server Component Identification 11 Rear Panel LEDs and Buttons Item Description Status 1 iLO activity Green = Activity exists. Flashing green

Strona 14 - System Board LEDs

110 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Unknown Problem Action: 1. Disconnect power to the server. 2. Follo

Strona 15

Troubleshooting 111 3. Refer to the device documentation to be sure the device is properly installed. For example, a third-party PCI or PCI-X board

Strona 16

112 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Internal System Problems List of Problems: CD-ROM and DVD Drive Probl

Strona 17 - Internal USB Connector

Troubleshooting 113 Data read from the drive is inconsistent, or drive cannot read data Action: 1. Clean the drive and media. 2. If a paper or pla

Strona 18 - )."

114 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Diskette drive cannot write to a diskette ...

Strona 19

Troubleshooting 115 Diskette drive light stays on Action: 1. Be sure no loose connections (on page 108) exist. 2. Be sure the diskette is not dama

Strona 20

116 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide on the front of the drive and look inside to see that the drive

Strona 21 - Statuses (on page 21

Troubleshooting 117 − To examine the drive take-up leader, tilt the cartridge receiver door on the front of the drive and look inside to see that t

Strona 22 - Fan Module Locations

118 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide server documentation for further requirements. NOTE: It is reco

Strona 23

Troubleshooting 119 4. Be sure no POST error messages ("POST Error Messages and Beep Codes" on page 186) are displayed while booti

Strona 24

12 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Item Description Status 7 UID button/LED Blue = Identification is a

Strona 25 - Server Operations

120 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide System completes POST but hard drive fails Action: 1. Be sure no loo

Strona 26

Troubleshooting 121 2. Be sure no viruses exist on the server. Run a current version of a virus scan utility. Server response time is slower than

Strona 27 - Removing the Access Panel

122 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide General memory problems are occurring Action: • Be sure the memory

Strona 28 - Installing the Access Panel

Troubleshooting 123 4. Be sure no operating system errors are indicated. 5. Restart the server and check to see if the error message is still disp

Strona 29 - Server Operations 29

124 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide PPM Problems Action: If the PPMs are not integrated on the system boa

Strona 30

Troubleshooting 125 5. If the server has only one processor installed, replace it with a known functional processor. If the problem is resolved aft

Strona 31 - Server Setup

126 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide • Be sure no loose connections (on page 108) exist in the rest of th

Strona 32 - Rack Planning Resources

Troubleshooting 127 on the server and to the monitor. − For tower-model servers, check the cable connection from the monitor to the server, a

Strona 33 - Optimum Environment

128 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide • Be sure the monitor and any KVM switch are compatible with the VGA

Strona 34 - Temperature Requirements

Troubleshooting 129 − For tower-model servers, check the cable connection from the input device to the server. 2. If a KVM switching device is in

Strona 35 - Power Requirements

Server Component Identification 13 Item Description Item Description 7 SCSI backplane connector* 15 PCI riser board assembly connector (for slot 1

Strona 36 - Rack Warnings

130 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide No response occurs when you type AT commands...

Strona 37 - Installing Hardware Options

Troubleshooting 131 4. Be sure you are in terminal mode and not MS-DOS mode. 5. Refer to the HP website (http://www.hp.com) for a complete list of

Strona 38

132 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Modem disconnects while online Action: 1. Be sure no loose connectio

Strona 39 - Server Setup 39

Troubleshooting 133 3. If this does not work, force a slower baud rate (14400 baud) with the AT command AT&Q6N0S37=11. You are unable to conne

Strona 40

134 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 7. Check the PCI Hot Plug power LED to be sure the PCI slot is recei

Strona 41 - Registering the Server

Troubleshooting 135 a. Uninstall the network controller driver for the malfunctioning controller in the operating system. b. Restart the server, r

Strona 42

136 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Restoring to a Backed-Up Version (on page 138) When to Reconfigure or

Strona 43 - Processor Option

Troubleshooting 137 1. Type the following commands at the System Console screen (where XXX is the new numeric value): Set Minimum Packet Receive Bu

Strona 44

138 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Restoring to a Backed-Up Version If you recently upgraded the operati

Strona 45

Troubleshooting 139 Errors occur after the system software is changed ...140

Strona 46 - Memory Options

14 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide NMI Switch The NMI switch allows administrators to perform a memory du

Strona 47 - DIMM Installation Guidelines

140 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Software locks up Action: 1. Check the application log and operating

Strona 48 - Installing DIMMs

Troubleshooting 141 • Be sure you have the most current drivers ("Maintaining Current Drivers" on page 141). Clustering Software If the

Strona 49 - Hard Drive Options

142 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide • Microsoft® operating systems—PSPs are available for servers runnin

Strona 50

Troubleshooting 143 • An administrative user account on each target system. The administrative account must have the same username and password as

Strona 51 - Optical Device Option

144 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Network connection fails on remote communication Because network conn

Strona 52

Troubleshooting 145 • You want to change the operating system selection. • You encounter a failure-causing error during the SmartStart installatio

Strona 53

146 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide on page 147) • Outside North America, call the nearest HP Tech

Strona 54

Troubleshooting 147 revision Operating System Information You Need Depending on the problem, you may be asked for certain pieces of informatio

Strona 55

148 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide • A list of each third-party software component installed, with the

Strona 56

Troubleshooting 149 − Version of the PSP used − List of drivers from the PSP (/var/log/hppldu.log) • A list of each third-party hardware componen

Strona 57 - Expansion Board Options

Server Component Identification 15 Item LED Description Status 3 DIMM 2A failure Amber = DIMM has failed. Off = DIMM is operating normally. 4 DI

Strona 58

150 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide − SYS:SYSTEM\SURVEY.TXT • Current patch level • A list of each thi

Strona 59

Troubleshooting 151 • A list of each third-party hardware component installed, with the firmware revisions • A list of each third-party software c

Strona 60

152 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide − File system on each logical drive • Warp Server version used and:

Strona 61 - Item Description

Troubleshooting 153 Board in Use by Expand Operation...

Strona 62

154 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Cache Has Been Disabled Because ADG Enabler Dongle is Broken or Missi

Strona 63 - Server Cabling

Troubleshooting 155 Logical Drive X Status = Overheating ...171L

Strona 64 - SATA Cable Routing

156 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Attached Drives...

Strona 65 - Configuration Tools

Troubleshooting 157 Accelerator Error Log Description: List of the last 32 parity errors on transfers to or from the memory on the array accelerator

Strona 66

158 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Description: Data in cache was lost, but not because of the battery b

Strona 67 - ROM-Based Setup Utility

Troubleshooting 159 Description: The number of cache lines experiencing excessive ECC errors has reached a preset limit. Therefore, the cache has be

Strona 68

16 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Item LED Description Status 14 Online spare memory Amber = Failover h

Strona 69

160 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Accelerator Status: Possible Data Loss in Cache Description: Possible

Strona 70 - Array Configuration Utility

Troubleshooting 161 Adapter/NVRAM ID Mismatch Description: EISA NVRAM has an ID for a different controller from the one physically present in the sl

Strona 71 - HP ProLiant Essentials RDP

162 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Cache Has Been Disabled Because ADG Enabler Dongle is Broken or Missi

Strona 72 - Management Tools

Troubleshooting 163 Controller Communication Failure Occurred Description: Controller communication failure occurred. ADU was unable to successfully

Strona 73 - ROMPaq Utility

164 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Controller Is Not Configured Description: Controller is not configure

Strona 74

Troubleshooting 165 Drive (Bay) X Firmware Needs Upgrading Description: Firmware on this physical drive is below the latest recommended version. Ac

Strona 75 - Erase Utility

166 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Drive (Bay) X is a Replacement Drive Description: This drive has been

Strona 76 - Redundant ROM Support

Troubleshooting 167 Drive (Bay) X Upload Code Not Readable Description: An error occurred while ADU was trying to read the upload code information f

Strona 77

168 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Drive Time-Out Occurred on Physical Drive Bay X Description: ADU issu

Strona 78

Troubleshooting 169 Identify Logical Drive Data did not Match with NVRAM Description: The identify unit data from the array controller does not matc

Strona 79 - Diagnostic Tools

Server Component Identification 17 System LED and Color Internal Health LED Color Status DIMM failure, slot X (Amber) Red • DIMM in slot X has fai

Strona 80 - Integrated Management Log

170 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Less Than 75% of Batteries at Sufficient Voltage Battery Pack X Below

Strona 81 - Keeping the System Current

Troubleshooting 171 Logical Drive X Status = Interim Recovery (Volume Functional, but not Fault Tolerant) Description: A physical drive in this logi

Strona 82 - Care Pack

172 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Logical Drive X Status = Recovering (rebuilding data on a replaced dr

Strona 83 - Battery Replacement

Troubleshooting 173 No Configuration for Array Accelerator Board Description: The array accelerator board has not been configured. Action: If the ar

Strona 84 - 5. Remove the battery

174 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Other Controller Indicates Different Cache Size Description: The othe

Strona 85 - Troubleshooting

Troubleshooting 175 SCSI Port X, Drive ID Y Has Exceeded the Following Threshold(s) Description: The monitor and performance threshold for this driv

Strona 86 - Symbols on Equipment

176 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide SCSI Port X, Drive ID Y RIS Copies Within This Drive Do Not Match Des

Strona 87 - Warnings and Cautions

Troubleshooting 177 Set Configuration Command Issued Description: The configuration of the array controller has been updated. The array accelerator

Strona 88

178 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Description: A power supply in the external storage unit has failed.

Strona 89 - Troubleshooting 89

Troubleshooting 179 Storage Enclosure on SCSI Bus X Indicated that the Fan is Degraded... ...SOLUTION: this condition usually occurs on enclosures w

Strona 90 - Symptom Information

18 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide For more information, refer to "Internal USB Functionality (on p

Strona 91 - Diagnostic Steps

180 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Description: You have exceeded the maximum number of drives supported

Strona 92 - General Diagnosis Flowchart

Troubleshooting 181 Description: One or more physical drives were moved, causing a configuration that is not supported. Action: Move all drives to t

Strona 93 - Troubleshooting 93

182 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Swapped Cables or Configuration Error Detected. The Maximum Logical V

Strona 94

Troubleshooting 183 4. Repeat these steps with the other controller. If both controllers give POST messages in one slot but not the other, it is a

Strona 95 - Troubleshooting 95

184 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Unable to Retrieve Identify Controller Data. Controller May be Disabl

Strona 96

Troubleshooting 185 WARNING - Drive Write Cache is Enabled on X Description: Drive has its internal write cache enabled. The drive may be a third-pa

Strona 97 - Troubleshooting 97

186 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Wrong Accelerator Description: This may mean that the board was repla

Strona 98

Troubleshooting 187 WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary information in the server documentation before

Strona 99 - Troubleshooting 99

188 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Unsupported Processor Detected System will ONLY boot ROMPAQ Utility.

Strona 100

Troubleshooting 189 Critical Error Occurred Prior to this Power-Up Audible Beeps: None Possible Cause: A catastrophic system error, which caused the

Strona 101 - Troubleshooting 101

Server Component Identification 19 Hot-Plug SCSI Hard Drive LEDs Item LED Description Status 1 Activity status On = Drive activity Flashing =

Strona 102

190 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Fatal Express Port Error Audible Beeps: None Possible Cause: A PCI Ex

Strona 103 - Troubleshooting 103

Troubleshooting 191 FATAL ROM ERROR: The System ROM is not Properly Programmed. Audible Beeps: 1 long, 1 short Possible Cause: The System ROM is not

Strona 104

192 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Internal CPU Check - Processor Audible Beeps: None Possible Cause: A

Strona 105 - Hardware Problems

Troubleshooting 193 NMI - Button Pressed! Audible Beeps: None Possible Cause: The NMI button was pressed, initiating a memory dump for crash dump an

Strona 106 - UPS is not working properly

194 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 2. Be sure no keys are depressed or stuck. 3. If the failure reoccu

Strona 107 - Troubleshooting 107

Troubleshooting 195 REDUNDANT ROM ERROR: Backup ROM Invalid. - ... ...run ROMPAQ to correct error condition. Audible Beeps: None Possible Cause: The

Strona 108

196 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Temperature violation detected - system Shutting Down in x seconds Au

Strona 109 - Troubleshooting 109

Troubleshooting 197 100 Series List of Messages: 101-I/O ROM Error...

Strona 110

198 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 102-System Board Failure, CMOS Test Failed. Audible Beeps: None Possi

Strona 111 - Troubleshooting 111

Troubleshooting 199 104-ASR Timer Failure Audible Beeps: None Possible Cause: System board failure. CAUTION: Only authorized technicians trained

Strona 112

© Copyright 2004 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties f

Strona 113 - Troubleshooting 113

20 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Hot-Plug SCSI Hard Drive LED Combinations Activity LED (1) Online

Strona 114

200 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 172-1-Configuration Non-volatile Memory Invalid Audible Beeps: None P

Strona 115 - Troubleshooting 115

Troubleshooting 201 201-Memory Error Audible Beeps: None Possible Cause: Memory failure detected. Action: Run Insight Diagnostics ("HP Insight

Strona 116 - Server cannot write to tape

202 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 207-Invalid Memory Configuration - DIMM Size Parameters Not Supported

Strona 117 - Troubleshooting 117

Troubleshooting 203 Audible Beeps: 1 long, 1 short Possible Cause: Installed DIMMs in the same bank are of different sizes. Action: Install correctl

Strona 118

204 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 209-Online Spare Memory Configuration - No Valid Banks for Online Spa

Strona 119 - Troubleshooting 119

Troubleshooting 205 300 Series List of Messages: 301-Keyboard Error...

Strona 120

206 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 303-Keyboard Controller Error Audible Beeps: None Possible Cause: Sys

Strona 121 - Troubleshooting 121

Troubleshooting 207 40X-Parallel Port X Address Assignment Conflict Audible Beeps: 2 short Possible Cause: Both external and internal ports a

Strona 122 - Memory count error exists

208 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 601-Diskette Controller Error Audible Beeps: None Possible Cause: Dis

Strona 123 - Troubleshooting 123

Troubleshooting 209 611-Primary Floppy Port Address Assignment Conflict Audible Beeps: 2 short Possible Cause: A hardware conflict in the system is

Strona 124

Server Component Identification 21 Optional Battery-Backed Write Cache Enabler LEDs Item LED Color 1 Amber 2 Green For LED status information,

Strona 125 - Troubleshooting 125

210 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 1151-Com Port 1 Address Assignment Conflict Audible Beeps: 2 short Po

Strona 126

Troubleshooting 211 Audible Beeps: None Possible Cause: Real-time clock system battery has lost power. The system will lose its configuration every

Strona 127 - Troubleshooting 127

212 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Audible Beeps: None Possible Cause: Required fan not spinning. Action

Strona 128 - Printer output is garbled

Troubleshooting 213 1611-Fan x Failure Detected (Fan Zone I/O) Audible Beeps: 2 short Possible Cause: Required fan not installed or spinning. Action

Strona 129 - Troubleshooting 129

214 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 1611- Power Supply Zone Fan Assembly Failure Detected. Either... ...t

Strona 130 - No dial tone exists

Troubleshooting 215 1611-Redundant Fan Failure (Fan Zone System) Audible Beeps: None Possible Cause: A redundant fan is not spinning. Action: Replac

Strona 131 - Troubleshooting 131

216 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide System AC Power Overload (Power Supply X)...

Strona 132

Troubleshooting 217 System Fan Failure (Fan X, Location) ...220S

Strona 133 - Troubleshooting 133

218 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide A CPU Power Module (System Board, Socket X)... ...A CPU Power Module

Strona 134

Troubleshooting 219 Event Type: System lockup Action: Refer to the operating system documentation. Corrected Memory Error Threshold Passed (Slot X,

Strona 135 - Software Problems

22 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Server Status LED Status Battery Module Status Server is on and is i

Strona 136 - Operating system locks up

220 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Processor Uncorrectable Internal Error (Slot X, Socket Y) Event Type:

Strona 137 - Troubleshooting 137

Troubleshooting 221 System Overheating (Zone X, Location) Event Type: Overheating condition Action: Check fans. System Power Supplies Not Redundant

Strona 139 - Troubleshooting 139

223 Electrostatic Discharge In This Section Preventing Electrostatic Discharge...

Strona 140

224 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Grounding Methods to Prevent Electrostatic Discharge Several methods

Strona 141 - Troubleshooting 141

225 Regulatory Compliance Notices In This Section Regulatory Compliance Identification Numbers...

Strona 142

226 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Federal Communications Commission Notice Part 15 of the Federal Commu

Strona 143 - Troubleshooting 143

Regulatory Compliance Notices 227 Class B Equipment This equipment has been tested and found to comply with the limits for a Class B digital device,

Strona 144

228 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide • Hewlett-Packard Company P. O. Box 692000, Mail Stop 510101 Houston

Strona 145 - Contacting HP

Regulatory Compliance Notices 229 Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Can

Strona 146

Server Component Identification 23 Processor Zone Fan Module LED Status Amber = One fan in this module has failed. Red = Multiple fans in this

Strona 147 - Troubleshooting 147

230 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Japanese Notice BSMI Notice Korean Notices Class A Equipment

Strona 148 - Linux Operating Systems

Regulatory Compliance Notices 231 Class B Equipment Laser Compliance This product may be provided with an optical storage device (that is, CD or

Strona 149 - Troubleshooting 149

232 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide • Do not try to open the module enclosure. There are no user-service

Strona 150 - SCO Operating Systems

233 Width 42.62 cm (16.78 in) Server Specifications In This Section Environmental Specifications...

Strona 151 - Troubleshooting 151

234 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Weight (maximum) 16.78 kg (37 lb) Weight (no drives installed) 12.4

Strona 152

235 Technical Support In This Section Related Documents...

Strona 154

237 Acronyms and Abbreviations ABEND abnormal end ACU Array Configuration Utility ASR Automatic Server Recovery BBWC battery-backed write cach

Strona 155 - Troubleshooting 155

238 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide iLO Integrated Lights-Out IML Integrated Management Log IPL initial

Strona 156

Acronyms and Abbreviations 239 PCI Express peripheral component interconnect express PCI-X peripheral component interconnect extended PDU power di

Strona 158

240 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide SCSI small computer system interface SDRAM synchronous dynamic RAM

Strona 159 - Troubleshooting 159

Acronyms and Abbreviations 241 VHDCI very high density cable interconnect WOL Wake-on LAN

Strona 161 - Troubleshooting 161

243 C cables 228 error messages 153, 186, 216 European Union notice 229 Index 1 120PCI.HAM 137 A AC power supply 54 access panel 2

Strona 162

244 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide IBM OS/2 151 IDE device 108 memory dump 14 memory slots 12

Strona 163 - Troubleshooting 163

Index 245 power LEDs, system 8 Power On/Standby button 7, 8, 25 ROM-Based Setup Utility (RBSU) 67, 112 ROMPaq utility 73, 76 Microsoft o

Strona 164

246 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide S safety considerations 36, 85 SATA connectors 12 SATA drives

Strona 165 - Troubleshooting 165

25 Server Operations In This Section Powering Up the Server...

Strona 166

26 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 4. Press the Power On/Standby button to place the server in standby m

Strona 167 - Troubleshooting 167

Server Operations 27 b. Secure the server by tightening the thumbscrews. 6. Reconnect the peripheral cables and power cords. Removing the Access

Strona 168

28 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Installing the Access Panel 1. Place the access panel on top of the s

Strona 169 - Troubleshooting 169

Server Operations 29 c. Lift the front of the assembly slightly and unseat the riser boards from the PCI riser board connectors. Installing PCI R

Strona 170

3 Electrical Grounding Requirements...36 Rack Warnings..

Strona 171 - Troubleshooting 171

30 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide

Strona 172

31 Server Setup In This Section Optional Installation Services...

Strona 173 - Troubleshooting 173

32 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide − HP ProLiant Essentials (HP SIM and RDP) − VMWare • Integrated har

Strona 174

Server Setup 33 − Coupling multiple racks • The Rack Products Documentation CD enables you to view, search, and print documentation for HP and C

Strona 175 - Troubleshooting 175

34 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide CAUTION: Always use blanking panels to fill empty vertical spaces i

Strona 176

Server Setup 35 • Do not permit optional equipment to impede airflow around the server or to increase the internal rack temperature beyond the ma

Strona 177 - Troubleshooting 177

36 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Electrical Grounding Requirements The server must be grounded properly

Strona 178

Server Setup 37 WARNING: To reduce the risk of personal injury or equipment damage when unloading a rack: • At least two people are needed to

Strona 179 - Troubleshooting 179

38 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Installing the Server into the Rack To install the server into a rack

Strona 180

Server Setup 39 Item Description 4 Power supply bay 1 (populated) 5 USB connector 6 10/100/1000 NIC 1 7 10/100/1000 NIC 2 8 iLO management p

Strona 181 - Troubleshooting 181

4 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Identifying the Server Shipping Carton Contents ...

Strona 182

40 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide While the server boots, RBSU and the ORCA utility are automatically co

Strona 183 - Troubleshooting 183

Server Setup 41 Registering the Server To register a server, refer to the registration card in the HP ProLiant Essentials Foundation Pack or the H

Strona 185 - Troubleshooting 185

43 Hardware Options Installation In This Section Introduction ...

Strona 186

44 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide The server uses embedded PPMs as DC-to-DC converters to provide the pr

Strona 187 - Troubleshooting 187

Hardware Options Installation 45 5. Remove the protective cover from the processor. 6. Align the holes in the processor assembly with the guidi

Strona 188

46 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 7. Install the processor assembly and close the processor locking lev

Strona 189 - Troubleshooting 189

Hardware Options Installation 47 DIMM Installation Guidelines You must observe the following guidelines when installing additional memory: • DIMM

Strona 190

48 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide After installing DIMMs, use RBSU to configure the system for online sp

Strona 191 - Troubleshooting 191

Hardware Options Installation 49 Hard Drive Options Removing a Hard Drive Blank (on page 49) SCSI Hard Drive Guidelines (on page 49) Installing a

Strona 192

Contents 5 Regulatory Compliance Identification Numbers...225 Feder

Strona 193 - Troubleshooting 193

50 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide • The SCSI ID for each hot-plug hard drive is set automatically to th

Strona 194

Hardware Options Installation 51 5. Resume normal server operations. Optical Device Option 1. Push the optical device ejector button and eject

Strona 195 - Troubleshooting 195

52 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Battery-Backed Write Cache Enabler Option The Battery-Backed Write Cac

Strona 196

Hardware Options Installation 53 5. Install the battery module over the fasteners and turn the fasteners clockwise to lock the module in place.

Strona 197 - Troubleshooting 197

54 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 8. Connect the battery module cable to the battery-backed write cache

Strona 198

Hardware Options Installation 55 2. Remove the power supply blank. 3. Remove the protective cover from the connector pins on the power supply.

Strona 199 - Troubleshooting 199

56 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 4. Install the redundant power supply into the bay until it clicks.

Strona 200

Hardware Options Installation 57 10. Be sure that the front panel external health LED is green ("Front Panel LEDs and Buttons" on page 8

Strona 201 - Troubleshooting 201

58 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Installing an Expansion Board 1. Power down the server ("Power

Strona 202

Hardware Options Installation 59 8. Install the expansion board into the slot until it seats firmly. IMPORTANT: If the expansion board ships wi

Strona 203 - Troubleshooting 203

6 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide FCC Rating Label...

Strona 204

60 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 5. Remove the expansion slot cover from the slot, if installed ("

Strona 205 - Troubleshooting 205

Hardware Options Installation 61 8. Identify the differences between the two PCI Express riser boards. Item Description 1 Riser board wi

Strona 206

62 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide a. Install the riser board with the slot for full-length boards onto

Strona 207 - Troubleshooting 207

63 Server Cabling In This Section Cabling Overview...

Strona 208

64 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide SATA Cable Routing CAUTION: When routing cables, always be sure t

Strona 209 - Troubleshooting 209

65 Server Software and Configuration Utilities In This Section Configuration Tools...

Strona 210

66 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide • Testing server hardware using the Insight Diagnostics Utility (&quo

Strona 211 - Troubleshooting 211

Server Software and Configuration Utilities 67 ROM-Based Setup Utility RBSU, an embedded configuration utility, performs a wide range of configura

Strona 212

68 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Auto-Configuration Process The auto-configuration process automaticall

Strona 213 - Troubleshooting 213

Server Software and Configuration Utilities 69 (http://www.compaq.com/support/techpubs/whitepapers/tm010301wp.html). Boot Options After the

Strona 214

7 Server Component Identification In This Section Front Panel Components ...

Strona 215 - Troubleshooting 215

70 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Array Configuration Utility ACU is a browser-based utility with the fo

Strona 216 - Event List Error Messages

Server Software and Configuration Utilities 71 For more information about array controller configuration, refer to the controller user guide, or t

Strona 217 - Troubleshooting 217

72 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 7. Enter the product ID and press the Enter key. 8. Press the Escape

Strona 218

Server Software and Configuration Utilities 73 ROMPaq Utility Flash ROM enables you to upgrade the firmware (BIOS) with system or option ROMPaq ut

Strona 219 - Troubleshooting 219

74 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Integrated Lights-Out Technology The iLO subsystem is a standard compo

Strona 220

Server Software and Configuration Utilities 75 HP recommends using DNS/DHCP with iLO to simplify installation. If DNS/DHCP cannot be used, use the

Strona 221 - Troubleshooting 221

76 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide The Erase Utility can be accessed from the Software and Drivers Downlo

Strona 222

Server Software and Configuration Utilities 77 NOTE: The server ships with the same version programmed on each side of the ROM. Safety and Secur

Strona 223 - Electrostatic Discharge

78 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide When the server boots, the system identifies whether the current ROM b

Strona 224 - Discharge

Server Software and Configuration Utilities 79 Internal USB Functionality An internal USB connector is available for use with USB drive keys only.

Strona 225

8 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Item Description 1 Diskette drive bay 2 Optical device bay 3 Front U

Strona 226 - Class A Equipment

80 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Array Diagnostic Utility ADU is a Windows-based tool that collects inf

Strona 227 - Class B Equipment

Server Software and Configuration Utilities 81 Keeping the System Current List of Tools: Drivers ...

Strona 228 - Mouse Compliance Statement

82 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Resource Paqs Resource Paqs are operating system-specific packa

Strona 229 - European Union Notice

83 Battery Replacement If the server no longer automatically displays the correct date and time, you may need to replace the battery that provide

Strona 230 - Korean Notices

84 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 5. Remove the battery. IMPORTANT: Replacing the system board batter

Strona 231 - Laser Compliance

85 Troubleshooting In This Section Server Diagnostic Steps...

Strona 232 - Battery Replacement Notice

86 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Important Safety Information Before servicing this product, read th

Strona 233 - Server Specifications

Troubleshooting 87 49-109 kg 100-240 lb This symbol indicates that the component exceeds the recommended weight for one individual to handle safely.

Strona 234

88 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide • The leveling jacks are extended to the floor. • The full weight of

Strona 235 - Technical Support

Troubleshooting 89 • Observe local occupation health and safety requirements and guidelines for manual handling. • Obtain adequate assistance to l

Strona 236

Server Component Identification 9 Item Description Status 3 Internal health LED Green = System health is normal. Amber = System is degraded. To i

Strona 237 - Acronyms and Abbreviations

90 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 6. Collect all tools and utilities, such as a Torx screwdriver, loopb

Strona 238

Troubleshooting 91 Diagnostic Steps To effectively troubleshoot a problem, HP recommends that you start with the first flowchart in this section, &q

Strona 239

92 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide General Diagnosis Flowchart The General Diagnosis flowchart provides

Strona 240

Troubleshooting 93 Item Refer to 1 "Symptom Information" 2 "Loose Connections (on page 108)" 3 "Service Notifications&q

Strona 241 - Wake-on LAN

94 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide

Strona 242

Troubleshooting 95 Power-On Problems Flowchart Symptoms: • The server does not power on. • The system power LED is off or amber. • The external h

Strona 243

96 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide Item Refer to 7 • "Power Supply Problems (on page 106)" •

Strona 244

Troubleshooting 97

Strona 245

98 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide POST Problems Flowchart Symptoms: • Server does not complete POST N

Strona 246

Troubleshooting 99